Electromagnetic Flowmeter AFLO-MAG

Electromagnetic Flowmeter AFLO-MAG

  • Measured Media Conductive fluids
  • Accuracy ±0.5%FS
  • Electrical Conductivity ≥ 5 S / cm
  • Ambient Temperature – 20 … 60 °C
  • Display Graphic LCD
  • Protection IP65 / IP67
  • Description
  • Application Areas
  • Reviews (0)
  • Specifications
  • Brochure
  • User’s Guide
  • How It Works

Product Description

Electromagnetic Flowmeter AFLO-MAG offer reliable precise and inexpensive flow measurement on all electrically conductive liquids. Typical applications are found in all industries. E.g.:

  • Water sector: Potable water, treatment of chemicals, wastewater and sludge.
  • Food sector: Daily products, beer, wine, soft-drinks and fruit juices.
  • Chemical sector: Detergents, pharmaceuticals, acids, alkalies.
  • Other sectors: District heating, pulp and paper and mining slurries.

The sensor converts the flow into an electrical voltage proportional to the velocity of the flow. The sensor is built up of a stainless steel pipe, 2 coils, electrodes, an isolating liner, housing and where applicable, connection flanges.

  • AFLO-MAG electromagnetic flowmeters will help you do an easier job of managing flow.
  • Whether it is installation, managing operations or verifying continuous accuracy, customers rely on AFLO-MAG to improve the entire value chain of activities.
  • AFLO-MAG electromagnetic flowmeters are tunable and adjustable according to your needs.
  • Water sector: Potable water, treatment of chemicals, wastewater and sludge.
  • Food sector: Daily products, beer, wine, soft-drinks and fruit juices.
  • Chemical sector: Detergents, pharmaceuticals, acids, alkalies.
  • Other sectors: District heating, pulp and paper and mining slurries.

Reviews

There are no reviews yet.


Be the first to review “Electromagnetic Flowmeter AFLO-MAG”

Outputs

  • 4 - 20 mA       Standard
  • Pulse               Standard
  • Alarm             Standard
  • Frequency     Standard

Communication

  • RS485           Standard
  • RS232           Optional
  • Modbus        Optional
  • Profibus       Optional
  • GPRS            Optional
  • HART           Optional

Liner Materials

  • Polytetrafluoroethylene (PTFE)
  • Fluorinated Ethylene-Propylene (FEP)
  • Polyurethane
  • Neoprene
  • Hard Rubber

Electrodes Materials

  • Stainless Steel 316L
  • Hastelloy B
  • Hastelloy C
  • Titanium Alloy
  • Tantalum Alloy
  • Platinum-Iridium Alloy
  • Stainless Steel-Coated Wolfram Carbide

Transmitter Specifications

  • Measured Media Conductive fluids
  • Accuracy ±0.5%FS
  • Electrical Conductivity ≥ 5 S / cm
  • Ambient Temperature - 20 ... 60 °C
  • Power Consumption Max. 15VA
  • Flow Direction Bi-Direction
  • Control Push Buttons
  • Display Graphic LCD
  • Protection IP65 / IP67

Sensor Specifications

  • Process Connection DIN, ANSI, or Screw
  • Fluid Temperature -20 ... 120 °C*
  • Protection IP67 / IP68
  • Measuring Tube Stainless steel
  • Outer Casing Carbon Steel**

*For PTFE only

**Manufacturer Standard

Power Supply

  • 85 … 250 VAC               Standard
    16 … 36 VDC                 Optional
    3.6 V Lithium Battery Optional

Electromagnetic Flowmeter AFLO-MAG Brochure

Electromagnetic Flowmeter AFLO-MAG Quick Setup

Electromagnetic Flowmeter AFLO-MAG User Guide

The flow measuring principle is based on Faraday’s law of electromagnetic induction.aflo-faraday

Ui = When an electrical conductor of length L is moved at velocity v, perpendicular to the lines of flux through a magnetic field of strength B, the voltage Ui is induced at the ends of the conductor

Ui = L x B x v
Ui = Induced voltage
L = Conductor length = Inner pipe diameter = k1
B = Magnetic field strength = k2
v = Velocity of conductor (media)
k = k1 x k2
Ui = k x v, the electrode signal is directly proportional to the fluid velocity