Ultrasonic Flowmeter TFM5100-NG

The Transit Time Flow Meter TFM5100-NG  measures flow rate by calculating the spreading time of an ultrasonic wave in a liquid, going upstream and downstream into a pipe.
This flow meter is mostly used to measure the flow rate of homogeneous fluids, also with a quite high percentage of suspended solids.
  • Description
  • Application Areas
  • Reviews (0)
  • Specifications
  • Brochure

Product Description

The Transit Time Flow Meter TFM5100-NG  measures flow rate by calculating the spreading time of an ultrasonic wave in a liquid, going upstream and downstream into a pipe.
This flow meter is mostly used to measure the flow rate of homogeneous fluids, also with a quite high percentage of suspended solids.
High Accuracy measuring: Linearity: better than 0.5%, Repeatability: better than 0.2%, Accuracy: better than ±0.5% (for speed >0.5 mt/sec)
Wide measuring range: Several types of transducer to be selected, measuring pipe size from DN15mm to DN6000mm with four different types of sensors.
Internal data Logging: Automatic record of :
-the flow data of the last 512 days/128 Months/10 years.
-the power on/off time and corresponding flow rate of the last 32 times.
-working status of last 512 days
Battery Life: From 5 months to 5 years depending on the measurement cycle
Power Supply: 36 VDC BY BATTERY or 8….36VDC, 50 mA
Size/Protection Grade: 96×96×129 mm – IP68
Set-Up: By external keypad or by software via RS485
Output: OTC/4-20mA/RS485 output
Protocol: M-BUS, MODBUS, extended protocol
  • Water treatment
  • Slurry and Process water pumping
  • Flow balancing
  • Hydro-electric
  • Cooling,
  • Anti-fire stations
  • Water District Oil and chemical industries
  • Extraction industries
  • Food, paper and pharmaceutical industries
  • Car industries

Reviews

There are no reviews yet.


Be the first to review “Ultrasonic Flowmeter TFM5100-NG”

General Specifications

  • Operating: For clean liquids in a full pipes with Less than 1 % solids or gas bubbles, particles
  • Configuration: With external keypad
  • Display: 96 segments LCD display
  • Accuracy: ±0.5% of reading value, Linearity ±0.5 % , Repeatability: ± 0.2%
  • Mul-way Power Power Supply: 3.6V Li battery ; or 8-36 VDC power supply, when cut off the power supply, the battery will continue to work.
  • Outputs: RS-485, OCT, 4-20mA (optional)
  • Communication: MODBUS/METER-BUS protocol, General water meter protocol.
  • Operating Temp.: -10...70°C
  • High Protection Grade: Protection grade up to IP68, can work in 2 m of water
  • Other Functions: Automatically record the totalizer data of the day/ month / year; The power-on/off time and corresponding flow rate. Allow manual or automatic flow loss compensation, The instrument working status. Programmable built-in batch controller
  • Design of General Applications: Length of pipe design bases on general water meter, easy to replace

Transducer Specifications

  • Protection: IP68
  • Pipe Materials: Any metal or plastic sonic conducting material including carbon steel, stainless steel, ductile iron, cast iron, PVC, PVDF, fiberglass, copper, brass, aluminum and pipes with bonded liners including epoxy, rubber and Teflon
  • Transducer and Operating Ranges ; -30…+90°C (TL-1,TM-1,TS-2)  High temperature transducer ; -30…+160°C (HTM-1, HTS-1)
  • Transducer Moun. Kit: Includes set of stainless steel pipe clamps, coupling compound
  • Cable Length: Standart 6 m

 

Ultrasonic Flowmeter TFM5100-NG

Open chat
Merhaba
Size nasıl yardımcı olabiliriz?