Flow

  • Halfround Pipe Stoppers UR

    0 out of 5

    These pipe stoppers are due to their lenght suitable for sealing of hause connections and domestic pipe systems.

  • Cone Pipe Stoppers ULK

    0 out of 5

    Cone pipe stoppers have in comparison with classical pipe stoppers different construction, but their use is the same.

  • Cone Test Pipe Stoppers PULK

    0 out of 5

    Cone pipe stoppers have in comparison with classical pipe stoppers different construction, but their use is the same.

  • Flow Measurement System AFLO-RS

    0 out of 5
    • Ready-assembled flow measurement system without changing physical structure of manhole
    • Works in every kind of manhole, channel or dropping point
    • Suitable for water, wastewater, treated water and all kinds of liquids
    • Standard outputs 4-20mA, Pulse, Relays
    • Optional datalogger and online monitoring
  • AFLO-TT Ultrasonic Transit Time FlowmeterAFLO-TT Ultrasonic Transit Time Flowmeter

    Ultrasonic Transit Time Flowmeter AFLO-TT

    0 out of 5

    AFLO-TT Ultrasonic Transit Time Flowmeter is ideal to measure flow rate of clear, non-aerated fluids in full pipes. Works best on fluids that have less than 2% particulate or gas bubbles

    • User-Friendly Operating System
    • Works from the Outside of Common Pipe Materials
    • Works with Wide Range of Liquids
    • Wide Measuring Ranges Up to DN6000
    • Easy and Fast Mounting
  • Ultrasonic Flowmeter / Calorimeter TFM2100-NG

    0 out of 5

    Ultrasonic Flowmeter / Calorimeter TFM2100-NG measures flow rate by calculating the spreading time of an ultrasonic wave in a liquid, going upstream and downstream into a pipe. This flow meter is mostly used to measure the flow rate of homogeneous fluids, also with a quite high percentage of suspended solids.Clamp-on sensors: it is not necessary to stop the flow to install them; Wetted sensors.

  • Electromagnetic Flowmeter AFLO-MAG

    Electromagnetic Flowmeter AFLO-MAG

    0 out of 5
    • Measured Media Conductive fluids
    • Accuracy ±0.5%FS
    • Electrical Conductivity ≥ 5 S / cm
    • Ambient Temperature – 20 … 60 °C
    • Display Graphic LCD
    • Protection IP65 / IP67
  • Over Gear Flow Meter

    0 out of 5
    • Accuracy: 0.5%, 0.2%
    • Line size: 10~200mm
    • Capability of measuring high-temperature and high-viscosity liquid
    • Small pressure loss
    • Simple installation
  • N-Serie Mass Flowmeters

    0 out of 5

    Series N Mass Flow Sensor and IPT200 /  DPT100 transmitter are paired to constitute series N flow meter with accuracy in 0.2% or 0.15%.

  • P – Serie Mass Flowmeters

    0 out of 5

    P – Series Flow Meter consists of Series P Mass Flow Sensor and DPT Transmitter. The main features are as follows;

    • Applied to Liquids, Gases, Grout Mass Flow
    • Pipe sizes: DN10 – DN150
    • Flow Measuring Accuracy: ±0.1%
    • Density Measuring Accuracy: ±0.001g/cm2
    • Process Temperature Limits: -40°C…+200°C
  • Thermal Mass Flow Switch 7000NH – 7200NH

    0 out of 5

    Switch contact closure: 5 amp at 5 VDC & 115VAC
    Trip point accuracy: ± 1% of set point
    Fluid temperature range: -40° to 65°C
    Pressure rating, maximum: 500 PSI Std., > 500 PSI, special
    Input power requirement: 24 VDC @ 250 mA max., 230 VAC 50/50 Hz optional
    Flow Transmitter enclosure: IP66, 125 x 125 x 100 mm ABS plastic with polycarbonate cover
    Wetted materials: All 316 SS (ceramic, glass, & epoxy optional)

  • ultrasonic transit time flowmeter

    Ultrasonic Flowmeter/Calorimeter TFM3100 – F1

    0 out of 5
    The Transit Time Flow Meter TFM3100  measures flow rate by calculating the spreading time of an ultrasonic wave in a liquid, going upstream and downstream into a pipe.
    This flow meter is mostly used to measure the flow rate of homogeneous fluids, also with a quite high percentage of suspended solids.
    High accuracy measuring: Linearity: better than 0.5% Repeatability: better than 0.2%,  Accuracy: better than ± 1%
    Wide measuring range: Several types of transducers to be selected, measuring pipe sizes from DN15mm to DN6000mm with four different types of sensors + PT100 ohm when it works as heat meter.
    Italian or English menu: The different versions of TTFM100/2009 NEW GENERATION can support Italian or English display, easy to operate, in the near future other languages will be implemented.
    Power supply: 8….36 VDC or 10….30VAC
    Engineering Units: Flow: Imperial and metric – Calories: BTU; GJ; KW; KCal
    Dimensions / Protection Grade: 90 90 36mm / IP20
    Set-Up: By integrated keypad
    Output: Relay OCT/4-20mA/RS485
    Protocol: M-BUS, MODBUS